{"id":23179,"date":"2019-04-22T10:00:20","date_gmt":"2019-04-22T14:00:20","guid":{"rendered":"https:\/\/blogs.solidworks.com\/tech\/?p=23179"},"modified":"2019-03-28T12:28:53","modified_gmt":"2019-03-28T16:28:53","slug":"tricks-to-help-out-sheet-metal-fabricators-through-the-solidworks-flatten-tool","status":"publish","type":"post","link":"https:\/\/blogs.solidworks.com\/tech\/2019\/04\/tricks-to-help-out-sheet-metal-fabricators-through-the-solidworks-flatten-tool.html","title":{"rendered":"Tricks to help out Sheet Metal Fabricators through the SOLIDWORKS Flatten Tool"},"content":{"rendered":"<p>This blog is all about a recent client who has been in the HVAC (Heating, Ventilation, and Air Conditioning) industry,\u00a0 questioned if there was any possibility to take blank development for a 90 degree Elbow, Reducer, Wye connector etc. The answer is, yes. <a href=\"https:\/\/www.solidworks.com\/\">SOLIDWORKS<\/a> will make this easier and provide the best results. For the next few minutes, I am going to guide you to receive the exact results. Here we go.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-23223 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture1-1-300x183.png\" alt=\"Sheetmetal Fabricators\" width=\"300\" height=\"183\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture1-1-300x183.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture1-1-615x375.png 615w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture1-1-728x444.png 728w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture1-1.png 751w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignright wp-image-23226\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture4-1-300x260.png\" alt=\"HVAC Industry\" width=\"250\" height=\"217\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture4-1-300x260.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture4-1.png 480w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23224\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture2-1-300x282.png\" alt=\"HVAC Industry\" width=\"244\" height=\"230\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture2-1-300x282.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture2-1.png 424w\" sizes=\"auto, (max-width: 244px) 100vw, 244px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-23225\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture3-1-120x120.png\" alt=\"HVAC Industry\" width=\"217\" height=\"205\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture3-1-300x283.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture3-1.png 426w\" sizes=\"auto, (max-width: 217px) 100vw, 217px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>At first, I created a defined sketch [Path] for the required model dimension\u2019s on one plane and I defined a profile, on another plane.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23227\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture5-1-300x272.png\" alt=\"HVAC Industry\" width=\"250\" height=\"227\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture5-1-300x272.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture5-1.png 499w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23228\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture6-1-300x266.png\" alt=\"HVAC Industry\" width=\"250\" height=\"221\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture6-1-300x266.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture6-1.png 455w\" sizes=\"auto, (max-width: 250px) 100vw, 250px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Go to Sweep-&gt; \u00a0\u00a0Check the \u201cThin Feature\u201d and set the thickness value [say 1.2mm]. Then choose Circle as Profile and its respective Path. Instantly you will see the Elbow profile. Click OK.<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23230 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture8-1-300x185.png\" alt=\"HVAC Industry\" width=\"300\" height=\"185\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture8-1-300x185.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture8-1-615x378.png 615w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture8-1.png 621w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23229 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture7-1-300x220.png\" alt=\"HVAC Industry\" width=\"300\" height=\"220\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture7-1-300x220.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture7-1.png 563w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Then choose the Side Plane to make an open cut [refer image below]. This open cut is the root for blank development.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-23231 size-large\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1-615x346.png\" alt=\"HVAC Industry\" width=\"615\" height=\"346\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1-615x346.png 615w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1-300x169.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1-768x432.png 768w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1-728x410.png 728w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture9-1.png 1160w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \/><\/p>\n<p>Now the next step is to create a Split Sketch for Splitting the Bodies to develop blank for each profile. After a Sketch, go to Split-&gt; Choose the Sketch-&gt; Choose the Bodies to Split-&gt; Check out \u201cConsume Bodies\u201d-&gt; Click OK.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23235 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13-300x166.png\" alt=\"HVAC Industry\" width=\"300\" height=\"166\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13-300x166.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13.png 604w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23233 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture11-300x195.png\" alt=\"HVAC Industry\" width=\"300\" height=\"195\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture11-300x195.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture11-615x401.png 615w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture11.png 694w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Now we will see the splitter bodies [Cut List] in the Feature Manager Tree. Then go to <a href=\"https:\/\/www.egsindia.com\/solidworks-sheet-metal.php\">Sheetmetal<\/a>-&gt; Insert Bend-&gt; Choose an edge on any of the body-&gt; Click OK. \u00a0Go to Flatten-&gt; Choose the Body which we created Insert Bend-&gt; Click OK and you will see the instant Blank development of the same.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23234 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture12-300x175.png\" alt=\"HVAC Industry\" width=\"300\" height=\"175\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture12-300x175.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture12.png 598w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23235 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13-300x166.png\" alt=\"HVAC Industry\" width=\"300\" height=\"166\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13-300x166.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture13.png 604w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23236 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture14-300x254.png\" alt=\"HVAC Industry\" width=\"300\" height=\"254\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture14-300x254.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture14.png 553w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/> <img loading=\"lazy\" decoding=\"async\" class=\"alignleft wp-image-23237 size-medium\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture15-300x170.png\" alt=\"HVAC Industry\" width=\"300\" height=\"170\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture15-300x170.png 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture15-615x349.png 615w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/4\/Picture15.png 635w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>I would like to conclude that this blank development process will be a treasure for the Sheet Metal fabricators especially the <a href=\"https:\/\/blogs.solidworks.com\/tech\/2019\/03\/sheetmetal-fabricators-hvac-industry-vertical-solidworks-flatten-tool.html\">HVAC industry<\/a>. I would like to encourage you all to follow the same procedure for the other bodies and other design related to the above. Catch you on the next post &#8211; on SOLIDWORKS features. Thank you.<\/p>\n<p><strong><u><b>Note:\u00a0 <\/b><\/u><\/strong>I did this for a single body. The same procedure can be done for different body in a single design environment by using SOLIDWORKS Configuration. Try it out. Share your results in the comments below!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>This blog is all about a recent client who has been in the HVAC (Heating, Ventilation, and Air Conditioning) industry,\u00a0 questioned if there was any possibility to take blank development for a 90 degree Elbow, Reducer, Wye connector etc. The<\/p>\n... <a href=\"https:\/\/blogs.solidworks.com\/tech\/2019\/04\/tricks-to-help-out-sheet-metal-fabricators-through-the-solidworks-flatten-tool.html\">Continued<\/a>","protected":false},"author":238,"featured_media":23233,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[21],"tags":[2550,254,889],"class_list":["post-23179","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solidworks","tag-egs-india","tag-sheetmetal","tag-solidworks","avhec_catgroup-all"],"acf":[],"_links":{"self":[{"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/posts\/23179","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/users\/238"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/comments?post=23179"}],"version-history":[{"count":8,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/posts\/23179\/revisions"}],"predecessor-version":[{"id":23389,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/posts\/23179\/revisions\/23389"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/media\/23233"}],"wp:attachment":[{"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/media?parent=23179"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/categories?post=23179"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.solidworks.com\/tech\/wp-json\/wp\/v2\/tags?post=23179"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}