{"id":3278,"date":"2019-10-09T14:52:44","date_gmt":"2019-10-09T14:52:44","guid":{"rendered":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/?p=3278"},"modified":"2019-10-01T14:52:54","modified_gmt":"2019-10-01T14:52:54","slug":"sabes-como-crear-material-con-propiedades-de-chapa-en-solidworks","status":"publish","type":"post","link":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/solidworks-blog\/solidworks\/solidworks-2019\/sabes-como-crear-material-con-propiedades-de-chapa-en-solidworks\/","title":{"rendered":"\u00bfSabes como crear material con propiedades de chapa en SOLIDWORKS?"},"content":{"rendered":"<p><strong>SOLIDWORKS 2019<\/strong> permite automatizar la selecci\u00f3n de la fibra neutra de pliegue mediante la asignaci\u00f3n de par\u00e1metros de chapa met\u00e1lica a materiales personalizados. De este modo, podremos hacer cambiar la fibra neutra en base a un rango de dimensiones.<\/p>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: center;\"><span style=\"color: #008dd2;\"><strong>PASO 1. CONFIGURACI\u00d3N DEL MATERIAL PERSONALIZADO.<\/strong><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p>En primer lugar, hay que configurar el material personalizado. Podemos copiar un material de SOLIDWORKS para poderlo modificar. Para este ejemplo usaremos el acero AISI 1020.<\/p>\n<p>Una vez abrimos el material personalizado, hacemos click en la nueva pesta\u00f1a de chapa met\u00e1lica.<\/p>\n<p><a href=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3279 size-full\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1.jpg\" alt=\"\" width=\"802\" height=\"606\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1.jpg 802w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1-300x227.jpg 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1-768x580.jpg 768w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/1-728x550.jpg 728w\" sizes=\"auto, (max-width: 802px) 100vw, 802px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p>Desde aqu\u00ed podr\u00e1s a\u00f1adir propiedades de chapa met\u00e1lica con <strong>Tablas de Calibres, Pliegues, o Intervalos de espesor<\/strong>. Vamos a utilizar la opci\u00f3n de Intervalo de espesor. \u00c9sta nos permitir\u00e1 definir los rangos mediante una tabla como la siguiente:<\/p>\n<p><a href=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-3281 \" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2.jpg\" alt=\"\" width=\"836\" height=\"453\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2.jpg 1903w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2-300x163.jpg 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2-768x416.jpg 768w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2-1024x555.jpg 1024w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/2-728x395.jpg 728w\" sizes=\"auto, (max-width: 836px) 100vw, 836px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Se podr\u00e1n definir los rangos de dimensiones, unidades, opciones de fibra neutra de pliegue y su valor.<\/p>\n<p><strong>Debe prestarse atenci\u00f3n a la continuidad de los rangos<\/strong>. Estos deben ser continuos: si por ejemplo queremos crear rangos de 0 a 30, todos los valores tienen que estar definidos. No se podr\u00e1 crear un rango de 0 a 5 y otro de 20 a 30, porque se estar\u00edan omitiendo los valores de 5 a 20.<\/p>\n<p>&nbsp;<\/p>\n<h2 style=\"text-align: center;\"><span style=\"color: #008dd2;\"><strong>PASO 2. APLICAR EL MATERIAL CON PROPIEDADES DE CHAPA MET\u00c1LICA.<\/strong><\/span><\/h2>\n<p>&nbsp;<\/p>\n<p>Al crear una brida base, la operaci\u00f3n nos dar\u00e1 la opci\u00f3n de <strong>\u201cUtilizar par\u00e1metros de chapa met\u00e1lica del material\u201d<\/strong>. Una vez seleccionada la opci\u00f3n, veremos que la fibra neutra cambiar\u00e1 en funci\u00f3n del espesor definido.<\/p>\n<p>&nbsp;<\/p>\n<p><a href=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter size-full wp-image-3282\" src=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3.jpg\" alt=\"\" width=\"878\" height=\"524\" srcset=\"https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3.jpg 878w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3-300x179.jpg 300w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3-768x458.jpg 768w, https:\/\/blog-assets.solidworks.com\/uploads\/sites\/15\/2019\/10\/3-728x434.jpg 728w\" sizes=\"auto, (max-width: 878px) 100vw, 878px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Resumiendo, algunos aspectos que deberemos tener en cuenta son los siguientes:<\/p>\n<ul>\n<li>Para aplicar par\u00e1metros de chapa deberemos <strong>crear materiales personalizados.<\/strong><\/li>\n<li><strong>Los rangos de espesores deber\u00e1n ser continuos<\/strong>, quedando definidos en todos los puntos de la pieza.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>As\u00ed pues, queda visto como definir los par\u00e1metros de chapa met\u00e1lica a nivel del material puede hacer m\u00e1s fluido el proceso de dise\u00f1o.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\">\u00a1Hasta la pr\u00f3xima!<\/p>\n","protected":false},"excerpt":{"rendered":"<p>SOLIDWORKS 2019 permite automatizar la selecci\u00f3n de la fibra neutra de pliegue mediante la asignaci\u00f3n de par\u00e1metros de chapa met\u00e1lica a materiales personalizados. De este modo, podremos hacer cambiar la fibra neutra en base a un rango de dimensiones. &nbsp;<\/p>\n... <a href=\"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/solidworks-blog\/solidworks\/solidworks-2019\/sabes-como-crear-material-con-propiedades-de-chapa-en-solidworks\/\">Continuado<\/a>","protected":false},"author":425,"featured_media":3285,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[268],"tags":[61,195],"class_list":["post-3278","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-solidworks-2019","tag-solidworks-2019","tag-trucos"],"acf":[],"_links":{"self":[{"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/posts\/3278","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/users\/425"}],"replies":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/comments?post=3278"}],"version-history":[{"count":3,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/posts\/3278\/revisions"}],"predecessor-version":[{"id":3304,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/posts\/3278\/revisions\/3304"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/media\/3285"}],"wp:attachment":[{"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/media?parent=3278"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/categories?post=3278"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blogs.solidworks.com\/solidworkslatamyesp\/wp-json\/wp\/v2\/tags?post=3278"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}