[{"data":1,"prerenderedAt":109},["ShallowReactive",2],{"DUtnfRXktcz4Dt4OJt-2dsKphfMaIq6sMikQlZySgFg":3,"article_solidworks-support-monthly-news-february-2023_solidworks":10,"_apollo:default":107,"_apollo:identified":108},{"mailchimpAudience":4},{"actionUrl":5,"slug":6,"locale":7,"default":8,"__typename":9},"","solidworks-support-monthly-news-february-2023","en","https:\u002F\u002F3ds.us3.list-manage.com\u002Fsubscribe\u002Fpost?u=ed4601044e1936748c0d2aa6b&id=e5080ff9fe&f_id=002d4de2f0","MailchimpAudience",{"posts":11},{"nodes":12,"__typename":106},[13],{"id":14,"slug":6,"title":15,"uri":16,"excerpt":17,"locale":18,"featuredImage":21,"tableOfContents":29,"content":33,"date":34,"authorJobTitle":5,"author":35,"masterings":47,"globalTags":61,"products":80,"disciplines":91,"seo":95,"__typename":105},"cG9zdDoxOTg3Nw==","SOLIDWORKS® Support Monthly News – February 2023","\u002Fproducts\u002Fsolidworks\u002Fsolidworks-support-monthly-news-february-2023","\u003Cp>Hello to all, Welcome to the new edition of the SOLIDWORKS® Support…\u003C\u002Fp>\n",{"locale":19,"__typename":20},"en_US","Locale",{"node":22,"__typename":28},{"large":23,"__typename":24,"medium_large":23,"thumbnail":25,"srcSet":26,"sizes":27},"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fsolidworks.jpg.webp","MediaItem","https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fsolidworks-150x150.jpg.webp","https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fsolidworks.jpg.webp 588w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fsolidworks-300x168.jpg.webp 300w","(max-width: 588px) 100vw, 588px","NodeWithFeaturedImageToMediaItemConnectionEdge",[30,31,32],"Step 1: Update the Manage add-in|step-1-update-the-manage-add-in-0","Step 2: Update the Configuration file|step-2-update-the-configuration-file-1","Step 3: Manual synchronization|step-3-manual-synchronization-2","\u003Cli> New Add-in :\n\u003Cul class=\"wp-block-list\">\n\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\n\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003Cul class=\"wp-block-list\">\n\u003Cli>swpdm.dll\u003C\u002Fli>\n\u003Cli>Interop.epdm.dll\n\u003Cdiv class=\"wp-block-image\">\u003Cfigure class=\"size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C\u002Fdiv>\n\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\n\u003C\u002Ful>\n\u003C\u002Fli>\n\u003C\u002Ful>\n\u003C\u002Fli>\n\u003Cli>Hit OK on the add-in properties dialog\n\u003Cul class=\"wp-block-list\">\n\u003Cli>– Note the new version number\n\u003Cp>\u003Cdiv class=\"wp-block-image\">\u003Cfigure class=\"size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C\u002Fdiv>\n\u003C\u002Fp>\u003C\u002Fli>\n\u003Cli>Note the warning and hit OK\n\u003Cp>\u003Cdiv class=\"wp-block-image\">\u003Cfigure class=\"size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C\u002Fdiv>\n\u003C\u002Fp>\u003C\u002Fli>\n\u003C\u002Ful>\n\u003C\u002Fli>\n\u003C\u002Fol>\u003Ch2 class=\"wp-block-heading\" id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003Col class=\"wp-block-list\">\n\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\n\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\n\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\n\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\n\u003C\u002Fol>\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003Cdiv class=\"wp-block-image\">\u003Cfigure class=\"size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C\u002Fdiv>\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003Cdiv class=\"wp-block-image\">\u003Cfigure class=\"size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C\u002Fdiv>\u003Ch2 class=\"wp-block-heading\" id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003Chr class=\"wp-block-separator\">\u003Ch1 class=\"wp-block-heading\">3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003Chr class=\"wp-block-separator\">\u003Ch1 class=\"wp-block-heading\">4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003Cdiv class=\"ds-video\">\u003Ca data-3ds-videoplayer=\"modal\" href=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\" target=\"_blank\">\u003Cspan class=\"ImageCover Border Block\" style=\"background-image: url(\u002Fassets\u002Fimg\u002F3ds-default.webp); width:100%; height: 100%;\">\u003Cspan class=\"Btn--circle isCenter\">\u003Ci class=\"Icon Icon--playBig\">\u003C\u002Fi>\u003C\u002Fspan>\u003Cimg decoding=\"async\" src=\"\u002Fassets\u002Fimg\u002F3ds-default.webp\" alt=\"\" style=\"width:100%;\">\u003C\u002Fspan>\u003C\u002Fa>\u003C\u002Fdiv>\u003Col class=\"wp-block-list\">\n\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\n\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\n\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\n\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\n\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\n\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003Chr class=\"wp-block-separator\">\n\u003C\u002Fli>\n\u003C\u002Fol>\u003C!-- \u002Fwp:list-item -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->\u003C!-- \u002Fwp:list -->\u003Cli> All the necessary ports may be opened at the Server and client, and still, you may encounter the login error. In such cases, it is worth checking if the SQL Services are enabled and running properly.\n\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Check if the ‘SQL Server Browser’ found in ‘Services.msc’ is enabled and is running properly (Refer 1.6).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19885,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"32\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp\" alt=\"\" class=\"wp-image-19885\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp 1024w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-300x9.jpg.webp 300w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-768x24.jpg.webp 768w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10.jpg.webp 1381w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \u002F>\u003Cfigcaption>fig 1.6\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list-item -->\u003Cli>In SQL Server Configuration Manager, Navigate to ‘SQL Server Network Configuration’ and check if the ‘TCP\u002FIP’ and ‘Named Pipes’ is enabled for the SQL Server Instance (Refer Fig 1.7). It is often seen that for PDM Standard Vault (Since it uses SQL Express version), the ‘TCP\u002FIP’ is disabled and thus the error is seen while login into the vault.\n\u003C!-- wp:image {\"id\":19886,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"252\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp\" alt=\"\" class=\"wp-image-19886\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp 605w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11-300x125.jpg.webp 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \u002F>\u003Cfigcaption>fig 1.7\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip: When installing SQL Server as a Named Instance, you can configure the server from using a dynamic port to a fixed static port. (https:\u002F\u002Fmsdn.microsoft.com\u002Fen-us\u002Flibrary\u002Fms177440.aspx)\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> The error is also seen if the ODBC connection is unable to automatically find the TCP port to use the SQL Instance. If the database is hosted on a named SQL server instance (HOSTNAMEINSTANCENAME) you may have to create an ODBC alias and enter a fixed TCP port number for the SQL instance to correctly establish an ODBC connection. To resolve such scenarios, you may follow the recommended steps outlined in QA00000108739 in the Knowledge Base (Refer Fig 1.8).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19887,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp\" alt=\"\" class=\"wp-image-19887\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1-300x85.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.8\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list-item -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>2.What should a SOLIDWORKS® PDM administrator do following a SOLIDWORKS® Manage upgrade?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Rohit MAGAR\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>There are a few procedures to do after upgrading to SOLIDWORKS® Manage to make sure the new add-in is loaded and the records between Manage and PDM stay current.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-1-update-the-manage-add-in-0\">Step 1: Update the Manage add-in\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->\u003C!-- \u002Fwp:list -->\n\u003C!-- wp:list-item -->\u003Cli> All the necessary ports may be opened at the Server and client, and still, you may encounter the login error. In such cases, it is worth checking if the SQL Services are enabled and running properly.\n\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Check if the ‘SQL Server Browser’ found in ‘Services.msc’ is enabled and is running properly (Refer 1.6).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19885,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"32\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp\" alt=\"\" class=\"wp-image-19885\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp 1024w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-300x9.jpg.webp 300w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-768x24.jpg.webp 768w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10.jpg.webp 1381w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \u002F>\u003Cfigcaption>fig 1.6\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In SQL Server Configuration Manager, Navigate to ‘SQL Server Network Configuration’ and check if the ‘TCP\u002FIP’ and ‘Named Pipes’ is enabled for the SQL Server Instance (Refer Fig 1.7). It is often seen that for PDM Standard Vault (Since it uses SQL Express version), the ‘TCP\u002FIP’ is disabled and thus the error is seen while login into the vault.\n\u003C!-- wp:image {\"id\":19886,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"252\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp\" alt=\"\" class=\"wp-image-19886\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp 605w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11-300x125.jpg.webp 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \u002F>\u003Cfigcaption>fig 1.7\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip: When installing SQL Server as a Named Instance, you can configure the server from using a dynamic port to a fixed static port. (https:\u002F\u002Fmsdn.microsoft.com\u002Fen-us\u002Flibrary\u002Fms177440.aspx)\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> The error is also seen if the ODBC connection is unable to automatically find the TCP port to use the SQL Instance. If the database is hosted on a named SQL server instance (HOSTNAMEINSTANCENAME) you may have to create an ODBC alias and enter a fixed TCP port number for the SQL instance to correctly establish an ODBC connection. To resolve such scenarios, you may follow the recommended steps outlined in QA00000108739 in the Knowledge Base (Refer Fig 1.8).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19887,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp\" alt=\"\" class=\"wp-image-19887\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1-300x85.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.8\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>2.What should a SOLIDWORKS® PDM administrator do following a SOLIDWORKS® Manage upgrade?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Rohit MAGAR\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>There are a few procedures to do after upgrading to SOLIDWORKS® Manage to make sure the new add-in is loaded and the records between Manage and PDM stay current.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-1-update-the-manage-add-in-0\">Step 1: Update the Manage add-in\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>The next thing to check is whether the client can communicate with the server. You can either ping\u002Ftelnet Server machine or use the Connectivity Test Tool (Refer QA00000119794 in Knowledge Base) from the client machine (Refer Fig 1.4). If the PDM client machine is not able to communicate with the SQL Server, it is recommended to involve the IT team to look as if the necessary ports are open, and not blocked by any firewall.\n\u003C!-- wp:image {\"id\":19883,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"255\" height=\"615\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp\" alt=\"\" class=\"wp-image-19883\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp 255w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1-124x300.png.webp 124w\" sizes=\"auto, (max-width: 255px) 100vw, 255px\" \u002F>\u003Cfigcaption>fig 1.4\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip : You can go through the following matrix to see the list of necessary ports that should be opened to be able to communicate between a PDM Client machine and Server (Refer Fig 1.5).\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19884,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"203\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp\" alt=\"\" class=\"wp-image-19884\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1-300x99.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.5\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list-item -->\u003Cli> All the necessary ports may be opened at the Server and client, and still, you may encounter the login error. In such cases, it is worth checking if the SQL Services are enabled and running properly.\n\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Check if the ‘SQL Server Browser’ found in ‘Services.msc’ is enabled and is running properly (Refer 1.6).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19885,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"32\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp\" alt=\"\" class=\"wp-image-19885\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp 1024w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-300x9.jpg.webp 300w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-768x24.jpg.webp 768w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10.jpg.webp 1381w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \u002F>\u003Cfigcaption>fig 1.6\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In SQL Server Configuration Manager, Navigate to ‘SQL Server Network Configuration’ and check if the ‘TCP\u002FIP’ and ‘Named Pipes’ is enabled for the SQL Server Instance (Refer Fig 1.7). It is often seen that for PDM Standard Vault (Since it uses SQL Express version), the ‘TCP\u002FIP’ is disabled and thus the error is seen while login into the vault.\n\u003C!-- wp:image {\"id\":19886,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"252\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp\" alt=\"\" class=\"wp-image-19886\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp 605w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11-300x125.jpg.webp 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \u002F>\u003Cfigcaption>fig 1.7\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip: When installing SQL Server as a Named Instance, you can configure the server from using a dynamic port to a fixed static port. (https:\u002F\u002Fmsdn.microsoft.com\u002Fen-us\u002Flibrary\u002Fms177440.aspx)\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> The error is also seen if the ODBC connection is unable to automatically find the TCP port to use the SQL Instance. If the database is hosted on a named SQL server instance (HOSTNAMEINSTANCENAME) you may have to create an ODBC alias and enter a fixed TCP port number for the SQL instance to correctly establish an ODBC connection. To resolve such scenarios, you may follow the recommended steps outlined in QA00000108739 in the Knowledge Base (Refer Fig 1.8).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19887,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp\" alt=\"\" class=\"wp-image-19887\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1-300x85.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.8\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>2.What should a SOLIDWORKS® PDM administrator do following a SOLIDWORKS® Manage upgrade?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Rohit MAGAR\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>There are a few procedures to do after upgrading to SOLIDWORKS® Manage to make sure the new add-in is loaded and the records between Manage and PDM stay current.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-1-update-the-manage-add-in-0\">Step 1: Update the Manage add-in\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->\u003C!-- \u002Fwp:list-item -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Whenever you see the message ‘Could not access the database’ when login into the vault, it is important to go through the details of the error in the SOLIDWORKS® PDM Client log (Open Administration Tool, and Double Click on ‘Log File’ found under Local Settings). The next thing to check is the SQL Server details, as the instance\u002Fdatabase name may be incorrectly defined. We have seen some cases where during a server upgrade or Move\u002FRestore scenario, the SQL Server is pointing toward the old machine details, and just checking the error thoroughly can save a lot of time and this issue can be rectified immediately (Refer Fig 1.3.1 &#038; 1.3.2).\n\u003C!-- wp:image {\"id\":19881,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"410\" height=\"253\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108.png.webp\" alt=\"\" class=\"wp-image-19881\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108.png.webp 410w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108-300x185.png.webp 300w\" sizes=\"auto, (max-width: 410px) 100vw, 410px\" \u002F>\u003Cfigcaption>fig 1.3.1\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19882,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"163\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1.png.webp\" alt=\"\" class=\"wp-image-19882\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1-300x80.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.3.2\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:paragraph -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list-item -->\u003C!-- wp:paragraph -->\u003Cp>The location where the Server entries are found in Windows Registry location mentioned below :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>ComputerHKEY_LOCAL_MACHINESOFTWARESolidWorksApplicationsPDMWorks EnterpriseDatabases\u003Cvault name>\u003C\u002Fvault>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>ComputerHKEY_LOCAL_MACHINESOFTWAREWOW6432NodeSolidWorksApplicationsPDMWorks EnterpriseDatabases\u003Cvault name wp:separator>\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:paragraph -->\u003Cp>Caution: Incorrectly editing the registry can severely damage your operating system. The SOLIDWORKS Technical Support team strongly suggests that you back up the registry data before making any changes to the registry.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fvault>\u003C\u002Fli>\u003C!-- \u002Fwp:list -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list -->\n\u003C!-- wp:list-item -->\u003Cli>The next thing to check is whether the client can communicate with the server. You can either ping\u002Ftelnet Server machine or use the Connectivity Test Tool (Refer QA00000119794 in Knowledge Base) from the client machine (Refer Fig 1.4). If the PDM client machine is not able to communicate with the SQL Server, it is recommended to involve the IT team to look as if the necessary ports are open, and not blocked by any firewall.\n\u003C!-- wp:image {\"id\":19883,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"255\" height=\"615\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp\" alt=\"\" class=\"wp-image-19883\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp 255w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1-124x300.png.webp 124w\" sizes=\"auto, (max-width: 255px) 100vw, 255px\" \u002F>\u003Cfigcaption>fig 1.4\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip : You can go through the following matrix to see the list of necessary ports that should be opened to be able to communicate between a PDM Client machine and Server (Refer Fig 1.5).\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19884,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"203\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp\" alt=\"\" class=\"wp-image-19884\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1-300x99.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.5\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> All the necessary ports may be opened at the Server and client, and still, you may encounter the login error. In such cases, it is worth checking if the SQL Services are enabled and running properly.\n\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Check if the ‘SQL Server Browser’ found in ‘Services.msc’ is enabled and is running properly (Refer 1.6).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19885,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"32\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp\" alt=\"\" class=\"wp-image-19885\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp 1024w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-300x9.jpg.webp 300w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-768x24.jpg.webp 768w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10.jpg.webp 1381w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \u002F>\u003Cfigcaption>fig 1.6\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In SQL Server Configuration Manager, Navigate to ‘SQL Server Network Configuration’ and check if the ‘TCP\u002FIP’ and ‘Named Pipes’ is enabled for the SQL Server Instance (Refer Fig 1.7). It is often seen that for PDM Standard Vault (Since it uses SQL Express version), the ‘TCP\u002FIP’ is disabled and thus the error is seen while login into the vault.\n\u003C!-- wp:image {\"id\":19886,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"252\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp\" alt=\"\" class=\"wp-image-19886\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp 605w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11-300x125.jpg.webp 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \u002F>\u003Cfigcaption>fig 1.7\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip: When installing SQL Server as a Named Instance, you can configure the server from using a dynamic port to a fixed static port. (https:\u002F\u002Fmsdn.microsoft.com\u002Fen-us\u002Flibrary\u002Fms177440.aspx)\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> The error is also seen if the ODBC connection is unable to automatically find the TCP port to use the SQL Instance. If the database is hosted on a named SQL server instance (HOSTNAMEINSTANCENAME) you may have to create an ODBC alias and enter a fixed TCP port number for the SQL instance to correctly establish an ODBC connection. To resolve such scenarios, you may follow the recommended steps outlined in QA00000108739 in the Knowledge Base (Refer Fig 1.8).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19887,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp\" alt=\"\" class=\"wp-image-19887\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1-300x85.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.8\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>2.What should a SOLIDWORKS® PDM administrator do following a SOLIDWORKS® Manage upgrade?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Rohit MAGAR\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>There are a few procedures to do after upgrading to SOLIDWORKS® Manage to make sure the new add-in is loaded and the records between Manage and PDM stay current.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-1-update-the-manage-add-in-0\">Step 1: Update the Manage add-in\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->\u003C!-- \u002Fwp:list -->\u003C!-- wp:post-content -->\u003C!-- wp:paragraph -->\u003Cp>Hello to all,\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Welcome to the new edition of the SOLIDWORKS® Support Monthly News! This monthly news blog is co-authored by members of the SOLIDWORKS® Technical Support teams worldwide. Here is the list of topics covered in this month’s Blog :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>\nHow to Troubleshoot the error ‘Could not access the item in the database’ error, when login into the vault in SOLIDWORKS® PDM?\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>\nWhat should a SOLIDWORKS® PDM administrator do, following a SOLIDWORKS® Manage upgrade?\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>\nHow to Troubleshoot the error “SOLIDWORKS® needs a folder to store user data for hole wizard…” when using hole wizard hole?\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>\nUnderstanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023.\n\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>1. How to Troubleshoot the ‘Could not access the item in the database’ error, when login into the vault in SOLIDWORKS® PDM?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Danish Ahmed SHAIK\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>When trying to connect to a new\u002Fexisting vault in SOLIDWORKS® PDM, you may see this generic error where you cannot log into the vault view (Refer Fig 1.1). However, in this blog, we would be specifically focusing on the detailed error in the SOLIDWORKS® PDM Client log and would look at different ways to troubleshoot it (Refer Fig 1.2)\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19879,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"453\" height=\"277\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-123.png.webp\" alt=\"\" class=\"wp-image-19879\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-123.png.webp 453w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-123-300x183.png.webp 300w\" sizes=\"auto, (max-width: 453px) 100vw, 453px\" \u002F>\u003Cfigcaption>fig 1.1\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:image {\"id\":19880,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"410\" height=\"490\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-117.png.webp\" alt=\"\" class=\"wp-image-19880\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-117.png.webp 410w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-117-251x300.png.webp 251w\" sizes=\"auto, (max-width: 410px) 100vw, 410px\" \u002F>\u003Cfigcaption>fig 1.2\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>The error is usually observed on PDM client machines when the protocol,  that is required for communication between the SOLIDWORKS® PDM Client and SQL Server is absent OR it is not running. This is why it cannot communicate with the protocol and has trouble locating the Server\u002FInstance.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Note that SOLIDWORKS® PDM Client on the SQL Server computer may work fine because it does not need to communicate through TCP\u002FIP protocols.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":4} -->\u003Ch4>Let us check different ways\u002Fmethods to investigate and troubleshoot this issue :\n\u003C\u002Fh4>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Whenever you see the message ‘Could not access the database’ when login into the vault, it is important to go through the details of the error in the SOLIDWORKS® PDM Client log (Open Administration Tool, and Double Click on ‘Log File’ found under Local Settings). The next thing to check is the SQL Server details, as the instance\u002Fdatabase name may be incorrectly defined. We have seen some cases where during a server upgrade or Move\u002FRestore scenario, the SQL Server is pointing toward the old machine details, and just checking the error thoroughly can save a lot of time and this issue can be rectified immediately (Refer Fig 1.3.1 &#038; 1.3.2).\n\u003C!-- wp:image {\"id\":19881,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"410\" height=\"253\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108.png.webp\" alt=\"\" class=\"wp-image-19881\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108.png.webp 410w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-108-300x185.png.webp 300w\" sizes=\"auto, (max-width: 410px) 100vw, 410px\" \u002F>\u003Cfigcaption>fig 1.3.1\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19882,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"163\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1.png.webp\" alt=\"\" class=\"wp-image-19882\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-94-615x163-1-300x80.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.3.2\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>The location where the Server entries are found in Windows Registry location mentioned below :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>ComputerHKEY_LOCAL_MACHINESOFTWARESolidWorksApplicationsPDMWorks EnterpriseDatabases\u003Cvault name>\u003C\u002Fvault>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>ComputerHKEY_LOCAL_MACHINESOFTWAREWOW6432NodeSolidWorksApplicationsPDMWorks EnterpriseDatabases\u003Cvault name wp:separator>\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C!-- wp:paragraph -->\u003Cp>Caution: Incorrectly editing the registry can severely damage your operating system. The SOLIDWORKS Technical Support team strongly suggests that you back up the registry data before making any changes to the registry.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fvault>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>The next thing to check is whether the client can communicate with the server. You can either ping\u002Ftelnet Server machine or use the Connectivity Test Tool (Refer QA00000119794 in Knowledge Base) from the client machine (Refer Fig 1.4). If the PDM client machine is not able to communicate with the SQL Server, it is recommended to involve the IT team to look as if the necessary ports are open, and not blocked by any firewall.\n\u003C!-- wp:image {\"id\":19883,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"255\" height=\"615\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp\" alt=\"\" class=\"wp-image-19883\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1.png.webp 255w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-84-255x615-1-124x300.png.webp 124w\" sizes=\"auto, (max-width: 255px) 100vw, 255px\" \u002F>\u003Cfigcaption>fig 1.4\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip : You can go through the following matrix to see the list of necessary ports that should be opened to be able to communicate between a PDM Client machine and Server (Refer Fig 1.5).\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19884,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"203\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp\" alt=\"\" class=\"wp-image-19884\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-14-615x203-1-300x99.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.5\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> All the necessary ports may be opened at the Server and client, and still, you may encounter the login error. In such cases, it is worth checking if the SQL Services are enabled and running properly.\n\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Check if the ‘SQL Server Browser’ found in ‘Services.msc’ is enabled and is running properly (Refer 1.6).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19885,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"32\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp\" alt=\"\" class=\"wp-image-19885\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-1024x32.jpg.webp 1024w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-300x9.jpg.webp 300w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10-768x24.jpg.webp 768w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F7-10.jpg.webp 1381w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \u002F>\u003Cfigcaption>fig 1.6\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In SQL Server Configuration Manager, Navigate to ‘SQL Server Network Configuration’ and check if the ‘TCP\u002FIP’ and ‘Named Pipes’ is enabled for the SQL Server Instance (Refer Fig 1.7). It is often seen that for PDM Standard Vault (Since it uses SQL Express version), the ‘TCP\u002FIP’ is disabled and thus the error is seen while login into the vault.\n\u003C!-- wp:image {\"id\":19886,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"605\" height=\"252\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp\" alt=\"\" class=\"wp-image-19886\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11.jpg.webp 605w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F8-11-300x125.jpg.webp 300w\" sizes=\"auto, (max-width: 605px) 100vw, 605px\" \u002F>\u003Cfigcaption>fig 1.7\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp>Tip: When installing SQL Server as a Named Instance, you can configure the server from using a dynamic port to a fixed static port. (https:\u002F\u002Fmsdn.microsoft.com\u002Fen-us\u002Flibrary\u002Fms177440.aspx)\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> The error is also seen if the ODBC connection is unable to automatically find the TCP port to use the SQL Instance. If the database is hosted on a named SQL server instance (HOSTNAMEINSTANCENAME) you may have to create an ODBC alias and enter a fixed TCP port number for the SQL instance to correctly establish an ODBC connection. To resolve such scenarios, you may follow the recommended steps outlined in QA00000108739 in the Knowledge Base (Refer Fig 1.8).\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19887,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp\" alt=\"\" class=\"wp-image-19887\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1.jpg.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F9-6-615x174-1-300x85.jpg.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 1.8\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>2.What should a SOLIDWORKS® PDM administrator do following a SOLIDWORKS® Manage upgrade?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Rohit MAGAR\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>There are a few procedures to do after upgrading to SOLIDWORKS® Manage to make sure the new add-in is loaded and the records between Manage and PDM stay current.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-1-update-the-manage-add-in-0\">Step 1: Update the Manage add-in\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Remove existing Manage Add-in :\n\u003C!-- \u002Fwp:paragraph -->\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Professional Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Login to the vault that you connected with SOLIDWORKS® Manage and expand the Add-ins Node\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Select the previous add-in > Right-click > Remove\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19888,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"523\" height=\"345\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp\" alt=\"\" class=\"wp-image-19888\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124.png.webp 523w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-124-300x198.png.webp 300w\" sizes=\"auto, (max-width: 523px) 100vw, 523px\" \u002F>\u003Cfigcaption>fig 1 : Remove existing Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli> New Add-in :\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>Right-click Add-ins and click New Add-in\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Navigate to the SOLIDWORKS® Manage client installation (such as C:Program FilesSOLIDWORKS CorpSOLIDWORKS Manage Client) and select:\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>swpdm.dll\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Interop.epdm.dll\n\u003C!-- wp:image {\"id\":19889,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"272\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp\" alt=\"\" class=\"wp-image-19889\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-118-615x272-1-300x133.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 2 : New Add-in\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C!-- wp:paragraph -->\u003Cp> \u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Hit OK on the add-in properties dialog\n\u003C!-- wp:list -->\u003Cul class=\"UL\">\n\u003C!-- wp:list-item -->\u003Cli>– Note the new version number\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19890,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"615\" height=\"448\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp\" alt=\"\" class=\"wp-image-19890\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1.png.webp 615w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F3-109-615x448-1-300x219.png.webp 300w\" sizes=\"auto, (max-width: 615px) 100vw, 615px\" \u002F>\u003Cfigcaption>fig 3 : Add-In Version\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Note the warning and hit OK\n\u003C!-- wp:paragraph -->\u003Cp>\u003C!-- wp:image {\"id\":19891,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"401\" height=\"184\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp\" alt=\"\" class=\"wp-image-19891\" srcset=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95.png.webp 401w, https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F4-95-300x138.png.webp 300w\" sizes=\"auto, (max-width: 401px) 100vw, 401px\" \u002F>\u003Cfigcaption>fig 4: SOLIDWORKS PDM Warning\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\n\u003C\u002Fp>\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Ful>\u003C!-- \u002Fwp:list -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-2-update-the-configuration-file-1\">Step 2: Update the Configuration file\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>After loading the Manage add-in, you should also add the SOLIDWORKS® Manage Configuration  (.swmc) file to the add-in. This is necessary to accommodate SOLIDWORKS® PDM users that do not have a SOLIDWORKS Manage client installation. To load the configuration file, follow these steps:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Open the SOLIDWORKS® PDM Administration tool.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Expand the ‘Add-ins’ node > right-click on the Manage add-in ‘swm.swpdm’ file> click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Properties’ dialog box, go to the ‘Files’ page and then click ‘Add Files’\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>In the ‘Select Files’ dialog box, change the filter to ‘All Files (*.*)’, select the Manage Configuration file, and then click ‘Open’.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- wp:paragraph -->\u003Cp>Completing this action includes the configuration file with the add-in.  For a visual reference, see the attached image. If there are subsequent changes to the configuration file, you will need to remove this file from the add-in and then add a new configuration file.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19892,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F5-85-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19892\">\u003Cfigcaption>fig 5: Update the Configuration file\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Kill and restart any active PDM Clients and the new version of the add-in is loaded within SOLIDWORKS® PDM;\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19893,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large thumbnail wp-caption aligncenter\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"156\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F6-57-300x156-1.png.webp\" alt=\"\" class=\"wp-image-19893\">\u003Cfigcaption>fig 6: New version loaded\u003C\u002Ffigcaption>\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:heading {\"level\":2} -->\u003Ch2 id=\"step-3-manual-synchronization-2\">Step 3: Manual synchronization\u003C\u002Fh2>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Manage needs to synchronize with the vault database to import many details of the vault including users, groups, folder structures, variables and permissions.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Please refer the blog post for a step-by-step tutorial on how to start a synchronization. Link : \u003Ca href=\"http:\u002F\u002Fblogs.solidworks.local\u002Ftech\u002F2021\u002F12\u002Fsolidworks-support-monthly-news-december-2021.html\" data-id=\"19896\">How to perform synchronization between SOLIDWORKS Manage and SOLIDWORKS PDM?\u003C\u002Fa>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>3. How to Troubleshoot error “SOLIDWORKS needs a folder to store user data for hole wizard…” when using hole wizard?\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Deepika PUJARI\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>A user has the ability to save a particular Hole Wizard hole as a ‘Hole Wizard Favorite’, instead of re-entering the parameters each time for the same hole.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>The error message, “SOLIDWORKS® needs a folder to store user data for Hole Wizard.  Since the default “data” folder does not have read-write privileges, please select a folder that does” This could be either due to Windows® user permissions set on the computer, or specifically the Hole Wizard Favorite’s folder not having read\u002Fwrite access.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>Windows user login needs to have read\u002Fwrite privileges at the location, where the hole wizard writes the default database file “HoleWizardFavourites.sldedb”. The default location for which is:\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>“C:Users\u003Cusername>AppDataRoamingSOLIDWORKSSOLIDWORKS 20XX”\u003C\u002Fusername>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19894,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"174\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F1-125-300x174-1.png.webp\" alt=\"\" class=\"wp-image-19894\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>User can also define a different location through Tools Menu > Options > File Location > Hole Wizard Favorite Database. Refer below image for example :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:image {\"id\":19895,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\u003Cfigure class=\"wp-block-image size-large\">\u003Cimg loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"235\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002F2-119-300x235-1.png.webp\" alt=\"\" class=\"wp-image-19895\">\u003C\u002Ffigure>\u003C!-- \u002Fwp:image -->\u003C!-- wp:paragraph -->\u003Cp>Ensuring read\u002Fwrite permissions to the specified location shall resolve this issue.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\u003C!-- wp:heading {\"level\":1} -->\u003Ch1>4. Understanding “View Collections” functionality in SOLIDWORKS® COMPOSER 2023\n\u003C\u002Fh1>\u003C!-- \u002Fwp:heading -->\u003C!-- wp:paragraph -->\u003Cp>\u003Cem>Author: Richie MORE\u003C\u002Fem>\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>SOLIDWORKS® Composer helps demonstrates a product’s functional process.\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:paragraph -->\u003Cp>What’s New in SOLIDWORKS® Composer 2023 has the ability to categorize the Views into collections. This helps the user segregate \u002F organize the views as per requirement which results in easy interactions of views available in the Project file within Views Pane. I have explained this with help of the following video :\u003C\u002Fp>\u003C!-- \u002Fwp:paragraph -->\u003C!-- wp:video {\"id\":19896} -->\u003Cfigure class=\"wp-block-video\">\u003Cvideo controls=\"\" src=\"https:\u002F\u002Fblog-assets.solidworks.com\u002Fuploads\u002F2025\u002F02\u002Fcomplete-february-2023.mp4\">\u003C\u002Fvideo>\u003C\u002Ffigure>\u003C!-- \u002Fwp:video -->\u003C!-- wp:list {\"ordered\":true} -->\u003Col class=\"wp-block-list\">\n\u003C!-- wp:list-item -->\u003Cli>Create Collection – To create a View Collection. Select the “ Create View Collection ” in View Pane heads-up bar (OR) ‘Right Click’ View > Add Collection .\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Rename Collection –  To Rename a View Collection : ‘Right click’ the Collection name  > Rename Collection\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Drag Views into Collection – Easily move the Views from one collection to other : Single select or Multi-Select with Ctrl \u002F Shift > Drag to Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Activate \u002F Deactivate Collection – Useful to Activate a Collection or Deactivate it. ‘Right click’ the Collection name  > Activate \u002F Deactivate Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection – It deletes the Collection, however keeps the Views in it. ‘Right Click’ the Collection name > Delete Collection.\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C!-- wp:list-item -->\u003Cli>Delete Collection Views – It keeps the Collection, however deletes the Views in it.Right Click the Collection name > Delete Collection Views.\n\u003C!-- wp:separator -->\u003Chr class=\"wp-block-separator\">\u003C!-- \u002Fwp:separator -->\n\u003C\u002Fli>\u003C!-- \u002Fwp:list-item -->\n\u003C\u002Fol>\u003C!-- \u002Fwp:list -->\u003C!-- \u002Fwp:post-content -->","2023-02-08T06:18:38",{"node":36,"__typename":46},{"nicename":37,"description":38,"slug":37,"name":39,"firstName":40,"lastName":41,"avatar":42,"__typename":45},"akhilc","Mechanical Engineer with overall 5 years of experience in mechanical domain - Academics and Industry. 4+ years in Technical Support of Computer Aided Design and Supporting SOLIDWORKS suite of products. Certifications: 3DEXPERIENCE® Collaborative Industry Innovator, 3DEXPERIENCE® Industry Innovator, 3DEXPERIENCE® 3D Creator","Akhil C","Akhil","C",{"url":43,"__typename":44},"https:\u002F\u002Fsecure.gravatar.com\u002Favatar\u002F5ba2a8aa81ecf67396d87354991e96f3d927e19db95dc1481e375b7710d05b0b?s=96&d=mm&r=g","Avatar","User","NodeWithAuthorToUserConnectionEdge",{"nodes":48,"edges":55,"__typename":60},[49],{"id":50,"name":51,"slug":52,"uri":53,"__typename":54},"dGVybTo5Mg==","Resources","resources","\u002Fmastering\u002Fresources\u002F","Taxonomy_mastering",[56],{"isPrimary":57,"node":58,"__typename":59},false,{"id":50,"name":51,"slug":52,"uri":53,"__typename":54},"PostToTaxonomy_masteringConnectionEdge","PostToTaxonomy_masteringConnection",{"nodes":62,"__typename":79},[63,69,74],{"id":64,"name":65,"slug":66,"uri":67,"__typename":68},"dGVybTo5NjI4","3D Modeling","3d-modeling","\u002Ftags\u002F3d-modeling\u002F","Taxonomy_tag",{"id":70,"name":71,"slug":72,"uri":73,"__typename":68},"dGVybTo5NjU3","Product Data Management (PDM)","product-data-management-pdm","\u002Ftags\u002Fproduct-data-management-pdm\u002F",{"id":75,"name":76,"slug":77,"uri":78,"__typename":68},"dGVybTo5NjAz","SOLIDWORKS","solidworks","\u002Ftags\u002Fsolidworks\u002F","PostToTaxonomy_tagConnection",{"edges":81,"nodes":88,"__typename":90},[82],{"isPrimary":57,"node":83,"__typename":87},{"id":84,"name":76,"slug":77,"uri":85,"__typename":86},"dGVybTo1Ng==","\u002Fproducts\u002Fsolidworks\u002F","Taxonomy_product","PostToTaxonomy_productConnectionEdge",[89],{"id":84,"name":76,"slug":77,"uri":85,"__typename":86},"PostToTaxonomy_productConnection",{"nodes":92,"edges":93,"__typename":94},[],[],"PostToTaxonomy_disciplineConnection",{"canonical":5,"title":96,"metaDesc":5,"opengraphAuthor":5,"opengraphDescription":97,"opengraphTitle":15,"opengraphUrl":98,"opengraphSiteName":99,"opengraphPublishedTime":100,"opengraphModifiedTime":101,"twitterTitle":5,"twitterDescription":5,"readingTime":102,"metaRobotsNoindex":103,"__typename":104},"SOLIDWORKS® Support Monthly News – February 2023 - Blog Solidworks","Hello to all, Welcome to the new edition of the SOLIDWORKS® Support…","\u002Fproducts\u002Fsolidworks\u002Fsolidworks-support-monthly-news-february-2023\u002F","Blog Solidworks","2023-02-08T11:18:38+00:00","2025-02-11T05:25:06+00:00",7,"noindex","PostTypeSEO","Post","RootQueryToPostConnection",{},{},1776255519515]